Side-Power SE 60/185 S Bedienungsanleitung Seite 9

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 8
9
SE 60/185S ignition protected thruster assembly 1.0 - 2007
Explanation of electrical table
- All cable lengths are the total of + and - (to and from).
- Battery size is stated as minimum cold crank capacity, not Ah.
- Use slow fuse rated to hold stated Amp-Draw for min. 5 minutes.
* Cable size and main battery size when an extra bow battery with minimum the CCA mentioned as A is installed.
It is important that you use a good cable size and batteries with a high cranking capacity to feed the thruster, because it is the actual
voltage at the motor while running the thruster that decides the output rpm of the motor and thereby the actual thrust. Please see the
list below for advised min. sizes of cables and batteries. You can of course use larger cables for even better results.
A main switch (*C) that can take the load without noticable voltage drop must be installed in the main positive lead so the power
for the thruster can be turned off independently of the rest of the system when not on board or in emergencies. This should be placed
in an easily accessible place and the boats instructions should include information that this should be turned off like the other main
switches of the boat.
We also advice to install a fuse (*D) in the positive lead for protection agains short circuiting of the main cables. This fuse should be
of a adequate quality which normally means that it is physically large as these have less voltage drop than the simple / small ones. It
should be of the slow type and sized to take the amperage draw for atleast 5 minutes.
Remember to use ignition protected fuses and switches if tted in areas that require this feature.
A circuit breaker can be used instead of the fuse and main power switch as long as the functionality is the same.
The cable ends must be tted with terminals and these must be well isolated against contact with anything but the proper connection
point.
If the main switch and fuse are installed in the same gas area they also have to be ignition protected.
The negative / minus cable connects to the (-) terminal. Bolt M10. Tighten with 25 Nm / 18,43 lb/ft.
The positive / plus cable connects to the "+" terminal. Bolt M10. Tighten with 25 Nm / 18,43 lb/ft.
Electrical installation
Model Voltage Nominal
current
draw
Min. battery
CCA
>7m total + & - 7-14m total + & - 15-21m total + & - 22-28m total + & - 28-35m total + & - 36-45m total + & -
Min. Rec. Min. Rec. Min. Rec. Min. Rec. Min. Rec. Min. Rec.
SE60/185S 12 V 340 A DIN: 350
SAE:665
mm
2
AWG
35
1
50
1/0
60
2/0
95
3/0
95
3/0
2x 70
2x 2/0
120
4/0
2x95
2x 3/0
2x 95
2x 3/0
2x120
2x 4/0
2x120
2x 4/0
280*
24 V 170 A DIN: 175
SAE: 332
mm
2
AWG
25
1
35
1
25
1
35
1
25
1
35
1
35
1
50
1/0
50
1/0
60
2/0
60
2/0
70
2/0
Battery & cable recommendations:
Minimum and recommended cable dimensions can be identical due to safety margins and cable heat considerations for short cable lenghts.
* Minimum or recommended cable cross section in mm
2
9
SP55S2i ignition protected thruster assembly
1.1 - 2006
Explanation of electrical table
- All cable lengths are the total of + and - (to and from).
- Battery size is stated as minimum cold crank capacity, not Ah.
- Use slow fuse rated to hold stated Amp-Draw for min. 5 minutes.
* Cable size and main battery size when an extra bow battery with minimum the CCA mentioned as A is installed.
It is important that you use a good cable size and batteries with a high cranking capacity to feed the thruster, because it is the actual
voltage at the motor while running the thruster that decides the output rpm of the motor and thereby the actual thrust. Please see the list
below for advised min. sizes of cables and batteries. You can of course use larger cables for even better results.
A main switch (*C) that can take the load without noticable voltage drop must be installed in the main positive lead so the power for the
thruster can be turned off independently of the rest of the system when not on board or in emergencies. This should be placed in an easily
accessible place and the boats instructions should include information that this should be turned off like the other main switches of the boat.
We also advice to install a fuse (*D) in the positive lead for protection agains short circuiting of the main cables. This fuse should be of a
adequate quality which normally means that it is physically large as these have less voltage drop than the simple / small ones. It should
be of the slow type and sized to take the amperage draw for atleast 5 minutes.
Remember to use ignition protected fuses and switches if fitted in areas that require this feature.
A circuit breaker can be used instead of the fuse and main power switch as long as the functionality is the same.
The cable ends must be fitted with terminals and these must be well isolated against contact with anything but the proper connection point.
If the main switch and fuse are installed in the same gas area they also have to be ignition protected.
The negative / minus cable connects to the (-) terminal. Bolt M10. Tighten with 25 Nm / 18,43 lb/ft.
The positive / plus cable connects to the "+" terminal. Bolt M10. Tighten with 25 Nm / 18,43 lb/ft.
Electrical installation
Battery
12V or 24V
+
-
*D
*C
Counter Nut
Nut
Washer
Cable terminal
Washer
Counter Nut
Nut
Washer
35 mm2 60 mm2 95 mm2 95 mm2 120 mm2 120 mm2
AWG 1 AWG OO AWG OOO AWG OOOO AWG OOOO
2 x AWG OOOO
25 mm2 25 mm2 35 mm2 35 mm2 50 mm2 50 mm2
AWG 4 AWG 4 AWG 2 AWG 2 AWG 1 AWG 1
Min.Battery
CCA by Din
200 CCA Din
380 CCA SAE
200 CCA Din
380 CCA SA E
200 CCA Din
380 CCA SAE
250 CCA Din
475 CCA SAE
200 CCA Din
380 CCA SAE
400 CCA Din
760 CCA SAE
350 CCA Din
665 CCA SA E
Min.Battery
CCA by Din
12 V
330 A Din
627 A SAE
350 CCA Din
665 CCA SAE
24 V
160 A Din
304 A SAE
200 CCA Din
380 CCA SAE
SP55S2i
IP
Min. Cable
dim ension
Min.Battery
CCA by Din
350 CCA Din
665 CCA SAE
400 CCA Din
760 CCA SAE
400 CCA Din
760 CCA SAE
Min.Battery
CCA by DIN
Min. Cable
dim e nsion
Min. Cable
dim ens ion
Min.Battery
CCA by DIN
16 - 19m total
+
&
-
20 - 23m total
+
&
-
24 - 27m total
+
&
-
Mode l Voltage
Current
draw
Min. Cable
dim ens ion
Min.Battery
CCA by DIN
Min. Cable
dim ension
Min. Cable
dim ension
Table for selection of main cable,
battery, fuse and main-switch
sizes.
up to 7m total
+
&
-
8 - 11m total
+
&
-
12 - 15m total
+
&
-
Seitenansicht 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare